Product · Nodes

Sudden leaks, to tens of metres.

Small pressure nodes at existing gauge ports, timed to the millisecond, so the wave a leak sends can be timed.

In designDesigned and simulated. No hardware built yet.
1

Sudden leaks: 157 → 20 m typical error, in simulation

2

No gain on slow leaks

3

Outbound only. Nothing can command the line.

What it looks like

Six nodes, one edge box, your SCADA

km 0km 4km 8km 12km 16km 20EDGE BOXOUR SOFTWAREYOUR SCADAread onlyCONTROL ROOMadvice

Six nodes at places you can already reach: both ends and the four valve stations. They send out by mobile network. Nothing can send commands back.

Sudden leak

157 → 20 m

Typical location error, SCADA alone → with six nodes.

Slow, growing leak

No gain

130 m before, 137 m after. A slow leak sends no sharp wave to time.

Quality matters

5× noisier

A rougher sensor loses most of the gain and misses most small leaks. Do not save money on the sensor.

Simulation, 447 leaks. Node sampling 5 times a second, clock good to 5 ms. The 20 m figure is at the limit of what the simulator can resolve; expect worse on real pipe.

What it needs

  • A spare gauge port at each site
  • Mobile network coverage

What it is not

  • No node is built yet
  • Hazardous-area certification comes later, with a partner